Cabtek range of ATEX Cable Glands
IP67, for unarmoured cable, sealing of silicone type outer displacement seal, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way is flexible conduit, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP67, for unarmoured cable, sealing of silicone type outer displacement seal, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way flexible conduit, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way ridgid conduit female, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way ridgid conduit male, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way ridgid conduit female, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for unarmoured cable, sealing of silicone type outer displacement seal, cable way ridgid conduit male, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP67, for braided single wire armoured (SWA) and steel tape armoured (STA) cable, compression seal of silicone, armoured ring (also for SWA), in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP67, for single wire armoured (SWA) cable, compression seal of silicone, armoured ring, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP67, for braided steel tape armoured (STA) cable, compression seal of silicone, armoured ring, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for braided single wire armoured (SWA) steel tape armoured (STA) cable, displacement seal of silicone, armoured ring (also for SWA), in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for braided single wire armoured (SWA) steel tape armoured (STA) cable, displacement seal of silicone, armoured ring (also for SWA), cable way flexible conduit, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for braided single wire armoured (SWA) steel tape armoured (STA) cable, displacement seal of silicone, armoured ring (also for SWA), cable way ridgid conduit female, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP66, for braided single wire armoured (SWA) steel tape armoured (STA) cable, displacement seal of silicone, armoured ring (also for SWA), cable way ridgid conduit male, in Metric, NPT, BSP and PG, temperature range from -60°C up to +135°C.
IP67, for single wire armoured (SWA) cable, displacement seal of silicone, armoured ring, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for single wire armoured (SWA) cable, displacement seal of silicone, armoured ring, cable way flexible conduit, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for single wire armoured (SWA) cable, displacement seal of silicone, armoured ring, cable way ridgid conduit female, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for single wire armoured (SWA) cable, displacement seal of silicone, armoured ring, cable way ridgid conduit male, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP67, for braided, steel tape armoured (STA) cable, displacement seal of silicone, armoured ring, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for braided, steel tape armoured (STA) cable, displacement seal of silicone, armoured ring, cable way flexible conduit, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for braided, steel tape armoured (STA) cable, displacement seal of silicone, armoured ring, cable way ridgid conduit female, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for braided, steel tape armoured (STA) cable, displacement seal of silicone, armoured ring, cable way ridgid conduit male, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.
IP66, for unarmoured cable, outer displacement seal of silicone, in Metric, NPT, BSP and PG, temperature range from -60°C up to +125°C.